Jump to: Axiom AX | Quartz QX | Hawkeye HX
Axiom® AX Models
FM (C and US) approved Class I Division 1 Groups B,C,D Class II Division 1 Groups E,F,G
Series |
Sensor Modules |
Pneumatic Valve |
Override |
Pneumatic Temperature |
Enclosure |
Conduit |
Indicator |
|
92S |
DeviceNet VCT |
|
|
94S |
Foundation Fieldbus (Externally Powered) |
96S |
AS-Interface |
97S |
AS-Interface (with extended addressing) | |
|
Single Solenoid |
Dual Solenoid |
24VDC (0.5W) 96, 97 |
1D |
2D |
24VDC (1.8W) 92, 94, 95, 96 |
1B |
2B |
|
N | Internal momentary 0.7Cv | M | External momentary 0.7Cv | L | External latching 0.7Cv |
E |
Internal momentary 1.2Cv |
Y |
External momentary 1.2Cv |
G |
External latching 1.2Cv | |
S |
Standard |
T |
Extended Temp | |
A |
North America -Aluminum |
S |
North America -Stainless Steel | |
02 |
(2) 3/4” NPT |
05 |
(2) M25 | |
RA |
Red-Closed Green-Open |
GA |
Green-Closed Red-Open |
1A or 2A |
Three Way Flow Path | |
Series |
Sensor Modules |
Pneumatic Valve |
Override |
Pneumatic Temperature |
Enclosure |
Conduit |
Indicator |
|
93S |
Foundation Fieldbus (Bus Powered; I.S.) | |
|
Single Piezo |
Dual Piezo |
Piezo |
1A |
2A | |
N | Internal momentary 0.7Cv | M | External momentary 0.7Cv | L | External latching 0.7Cv |
E | Internal momentary 1.2Cv | Y | External momentary 1.2Cv | G | External latching 1.2Cv |
|
|
A |
North America -Aluminum |
S |
North America -Stainless Steel | |
02 |
(2) 3/4” NPT |
05 |
(2) M25 | |
RA |
Red-Closed Green-Open |
GA |
Green-Closed Red-Open |
1A or 2A |
Three Way Flow Path | |
Axiom AX with Sensors
Series |
Sensor Modules |
Pneumatic Valve |
Override |
Pneumatic Temperature |
Enclosure |
Conduit |
Indicator |
|
33 |
SST N.O. Switching Sensor | |
|
Single Solenoid |
Dual Solenoid |
24VDC or 120VAC Universal |
1H |
2H |
|
N |
Internal momentary 0.7Cv |
M |
External momentary 0.7Cv |
L |
External latching 0.7Cv | E | Internal momentary 1.2Cv | Y | External momentary 1.2Cv | G | External latching 1.2Cv |
|
S |
Standard |
T |
Extended Temp | |
A |
North America -Aluminum |
S |
North America -Stainless Steel | |
02 |
(2) 3/4” NPT |
05 |
(2) M25 | |
RA |
Red-Closed Green-Open |
GA |
Green-Closed Red-Open |
1A or 2A |
Three Way Flow Path | |
Series |
Sensor Modules |
Pneumatic Valve |
Override |
Pneumatic Temperature |
Enclosure |
Conduit |
Indicator |
|
44 |
Namur Sensor (I.S.; DIN 19234) | |
|
Single Solenoid |
Dual Solenoid |
12VDC I.S. |
1E |
2E |
|
N |
Internal momentary 0.7Cv |
M |
External momentary 0.7Cv |
L |
External latching 0.7Cv | E | Internal momentary 1.2Cv | Y | External momentary 1.2Cv | G | External latching 1.2Cv |
|
S |
Standard |
T |
Extended Temp | |
A |
North America -Aluminum |
S |
North America -Stainless Steel | |
02 |
(2) 3/4” NPT |
05 |
(2) M25 | |
RA |
Red-Closed Green-Open |
GA |
Green-Closed Red-Open |
1A or 2A |
Three Way Flow Path | |
Quartz® models
FM (C and US) approved Class I Division 1 Groups B,C,D Class II Division 1 Groups E,F,G
Explosionproof Quartz models (Aluminum Cover)
Series |
Sensors / Switches |
Enclosure |
Conduit Entries |
Output | Indicator |
QX |
Sensor Modules
33 |
SST N.O. Switching Sensor Dual Module |
35 |
SST Universal N.O. Switching Sensor Dual Module
|
44 |
Namur Sensors (new)Dual Module |
45 |
Namur Sensors (old) Dual Module |
Valve Communication Terminals (VCTs)
92 |
DeviceNet VCT |
93 |
Foundation Fieldbus (Bus Powered; I.S.) |
95 |
ModBus |
96 |
AS-Interface |
97 |
AS-Interface (with extended addressing) |
Non contact Position Transmitters
TO |
4-20mA digital position transmitter |
TT |
4-20mA digital position transmitter with SST Universal N.O. Switching Sensor Dual Module |
TR |
4-20mA digital position transmitter with Namur Sensor Dual Module |
Sensors / Switches
Function
2 |
(2) Switches |
4 |
(4) Switches |
5 |
Position Transmitter with (2) or No Switches |
7 |
High Performance Position Transmitter with (2) or No Switches |
8 |
Expeditor, Y, H, V, or W switches only | |
Switch / Sensor Type
V |
SPDT Mechanical |
W |
SPDT Gold Contact Mechanical |
P |
SPST Maxx-Guard |
L |
SPST Maxx-Guard (LED) |
J |
SPST Maxx-Guard (Passive) |
G* |
SPDT Maxx-Guard |
H |
SPDT Maxx-Guard |
S |
SPDT Maxx-Guard (LED) |
M |
SPDT Maxx-Guard (Passive) |
Y |
Expeditor Only (3) |
N |
Namur sensors P&F |
F |
PNP Solid State 3-wire P&F |
E |
NPN Solid State 3-wire P&F |
X |
SST Sensor (LED) |
O |
No Switches |
|
6V |
(6) SPDT Mechanical |
6W |
(6) SPDT Gold Contact Mechanical |
6X |
(6) SST Sensors (LED) |
2A |
(2) P&F Special safety amplifier |
|
E |
North American(NEC/CEC) |
S |
Stainless Steel North American(NEC/CEC | |
02 |
(1) 3/4” NPT & (1) 1/2” NPT |
03 |
(1) 3/4” NPT & (2) 1/2” NPT | |
S | Short visual indicator
| N | Extended Visual indicator |
|
RA |
Red-Closed Green-Open |
GA |
Green-Closed Red-Open |
1A |
T1 3-way |
2A |
T2 3-way |
3A |
T3 3-way |
4A |
T4 3-way |
5A |
T5 3-way |
0A |
No Indication |
XA |
Special |
CA |
Continuous |
|
Hawkeye® HX models FM (C and US) approved Class I Division 1 Groups A,B,C,D Class II Division 1 Groups E,F,G Series | Function | Enclosure | Conduit / Connectors | Features | HX | 35 | SST 240V sensor (NO Sensor) | 45 | Namur Sensor (EN 60947-5-6; I.S.) |
| S | North American (NEC/CEC) |
| | |
|
|
|