Jump to: Axiom
Quartz
Eclipse
Prism
Hawkeye
Axiom VCT's
Note: Add -T to model code for
extended temperature range ( -40C - 70C)
|
Series |
Sensor Modules |
Pneumatic
Valve |
Enclosure |
Conduit
|
Capabilities |
Indicator |
|
|
|
92
|
DeviceNet VCT
|
|
94
|
Foundation Fieldbus (Externally
Powered)
|
|
95
|
ModBus
|
|
96
|
AS-Interface
|
|
97
|
AS-Interface (with
extended addressing)
|
|
|
|
|
Single
Solenoid
| |
No Ext Override |
External Override |
Latching Ext. Over. |
24VDC (0.5W)
92, 94, 95,
96, 97 |
1D |
3D |
5D |
24VDC (1.8W)
92, 94, 95, 96, 97 |
1B |
3B |
5B |
Dual Solenoid Shuttle Piston
| |
No Ext Override |
External Override |
Latching Ext. Over. |
24VDC (1.8W)
92, 94, 95, 96, 97 |
2B |
4B |
6B |
24VDC (0.5W)
92, 94, 95, 96, 97 |
2D |
4D |
6D |
|
|
|
02
|
(2) 1/2”
NPT
|
|
05
|
(2) M20
|
|
10
|
(1) 4-pin Mini male connector
|
|
11
|
(1) 5-pin
Mini male connector
|
|
13
|
(1) 4-pin
Micro male connector
|
|
15
|
(1) 5-pin
Micro male connector
|
|
17
|
(1) 6-pin Micro male connector
|
|
18
|
(1) 8-pin Micro male connector
|
|
19
|
(1) 6-pin Mini male connector
|
|
20
|
(1) 7-pin Mini male connector
|
|
21
|
(1) 8-pin Mini male connector
|
|
|
|
RA
|
Red-Closed
Green-Open
|
|
GA
|
Green-Closed
Red-Open
|
|
1A or 2A |
Three Way Flow Path |
|
|
Series |
Sensor Modules |
Pneumatic
Valve |
Enclosure |
Conduit
|
Capabilities |
Indicator |
|
|
|
93
|
Foundation Fieldbus
(Bus Powered) |
|
Single Piezo
| |
No Ext Override |
External Override |
Latching Ext. Over. |
| Piezo |
1A |
3A |
5A |
Dual Piezo Shuttle Piston
| |
No Ext Override |
External Override |
Latching Ext. Over. |
| Piezo |
2A |
4A |
6A |
|
|
|
02
|
(2) 1/2”
NPT
|
|
05
|
(2) M20
|
|
10
|
(1) 4-pin Mini male connector
|
|
11
|
(1) 5-pin
Mini male connector
|
|
13
|
(1) 4-pin
Micro male connector
|
|
15
|
(1) 5-pin
Micro male connector
|
|
17
|
(1) 6-pin Micro male connector
|
|
18
|
(1) 8-pin Micro male connector
|
|
19
|
(1) 6-pin Mini male connector
|
|
20
|
(1) 7-pin Mini male connector
|
|
21
|
(1) 8-pin Mini male connector
|
|
|
|
RA
|
Red-Closed
Green-Open
|
|
GA
|
Green-Closed
Red-Open
|
|
1A or 2A |
Three Way Flow Path |
|
Axiom with
Sensors
Note: Add -T to model code for
extended temperature range ( -40C - 80C)
|
Series |
Sensor Modules |
Pneumatic
Valve |
Enclosure |
Conduit
|
Capabilities |
Indicator |
|
|
|
33
|
SST N.O. Switching Sensor |
|
Single
Solenoid
| |
No Ext Override |
External Override |
Latching Ext. Over. |
| 24VDC or 120VAC Universal |
1H |
3H |
5H |
Dual Solenoid Shuttle Piston
| |
No Ext Override |
External Override |
Latching Ext. Over. |
| 24VDC or 120VAC Universal |
2H |
4H |
6H |
|
|
|
02
|
(2) 1/2”
NPT
|
|
05
|
(2) M20
|
|
10
|
(1) 4-pin Mini male connector
|
|
11
|
(1) 5-pin
Mini male connector
|
|
13
|
(1) 4-pin
Micro male connector
|
|
15
|
(1) 5-pin
Micro male connector
|
|
17
|
(1) 6-pin Micro male connector
|
|
18
|
(1) 8-pin Micro male connector
|
|
19
|
(1) 6-pin Mini male connector
|
|
20
|
(1) 7-pin Mini male connector
|
|
21
|
(1) 8-pin Mini male connector
|
|
|
|
RA
|
Red-Closed
Green-Open
|
|
GA
|
Green-Closed
Red-Open
|
|
1A or 2A |
Three Way Flow Path |
|
|
Series |
Sensor Modules |
Pneumatic
Valve |
Enclosure |
Conduit
|
Capabilities |
Indicator |
|
|
|
44
|
Namur Sensor (I.S.;
DIN 19234)
|
|
Single
Solenoid
| |
No Ext Override |
External Override |
Latching Ext. Over. |
| 12VDC I.S. |
1E |
3E |
5E |
Dual Solenoid Shuttle Piston
| |
No Ext Override |
External Override |
Latching Ext. Over. |
| 12VDC I.S. |
2E |
4E |
6E |
|
|
|
02
|
(2) 1/2”
NPT
|
|
05
|
(2) M20
|
|
10
|
(1) 4-pin Mini male connector
|
|
11
|
(1) 5-pin
Mini male connector
|
|
13
|
(1) 4-pin
Micro male connector
|
|
15
|
(1) 5-pin
Micro male connector
|
|
17
|
(1) 6-pin Micro male connector
|
|
18
|
(1) 8-pin Micro male connector
|
|
19
|
(1) 6-pin Mini male connector
|
|
20
|
(1) 7-pin Mini male connector
|
|
21
|
(1) 8-pin Mini male connector
|
|
|
|
RA
|
Red-Closed
Green-Open
|
|
GA
|
Green-Closed
Red-Open
|
|
1A or 2A |
Three Way Flow Path |
|
Axiom VCT's
Note: Add -T to model code for
extended temperature range ( -40C - 80C)
|
Series |
Sensor Modules |
Pneumatic
Valve |
Enclosure |
Conduit
|
Capabilities |
Indicator |
|
|
|
96
|
AS-Interface
|
|
97
|
AS-Interface (with
extended addressing)
|
|
|
|
|
Single
Solenoid
| |
No Ext Override |
External Override |
Latching Ext. Over. |
24VDC (0.5W)
92, 94, 95,
96, 97 |
1D |
3D |
5D |
24VDC (1.8W)
92, 94, 95, 96, 97 |
1B |
3B |
5B |
Dual Solenoid Shuttle Piston
| |
No Ext Override |
External Override |
Latching Ext. Over. |
24VDC (1.8W)
92, 94, 95, 96, 97 |
2B |
4B |
6B |
24VDC (0.5W)
92, 94, 95, 96, 97 |
2D |
4D |
6D |
|
|
|
02
|
(2) 1/2”
NPT
|
|
05
|
(2) M20
|
|
10
|
(1) 4-pin Mini male connector
|
|
11
|
(1) 5-pin
Mini male connector
|
|
13
|
(1) 4-pin
Micro male connector
|
|
15
|
(1) 5-pin
Micro male connector
|
|
17
|
(1) 6-pin Micro male connector
|
|
18
|
(1) 8-pin Micro male connector
|
|
19
|
(1) 6-pin Mini male connector
|
|
20
|
(1) 7-pin Mini male connector
|
|
21
|
(1) 8-pin Mini male connector
|
|
|
|
RA
|
Red-Closed
Green-Open
|
|
GA
|
Green-Closed
Red-Open
|
|
1A or 2A |
Three Way Flow Path |
|
|
Series |
Sensor Modules |
Pneumatic
Valve |
Enclosure |
Conduit
|
Capabilities |
Indicator |
|
|
|
93
|
Foundation Fieldbus
(Bus Powered) |
|
Single Piezo
| |
No Ext Override |
External Override |
Latching Ext. Over. |
| Piezo |
1A |
3A |
5A |
Dual Piezo Shuttle Piston
| |
No Ext Override |
External Override |
Latching Ext. Over. |
| Piezo |
2A |
4A |
6A |
|
|
|
02
|
(2) 1/2”
NPT
|
|
05
|
(2) M20
|
|
10
|
(1) 4-pin Mini male connector
|
|
11
|
(1) 5-pin
Mini male connector
|
|
13
|
(1) 4-pin
Micro male connector
|
|
15
|
(1) 5-pin
Micro male connector
|
|
17
|
(1) 6-pin Micro male connector
|
|
18
|
(1) 8-pin Micro male connector
|
|
19
|
(1) 6-pin Mini male connector
|
|
20
|
(1) 7-pin Mini male connector
|
|
21
|
(1) 8-pin Mini male connector
|
|
|
|
RA
|
Red-Closed
Green-Open
|
|
GA
|
Green-Closed
Red-Open
|
|
1A or 2A |
Three Way Flow Path |
|
Nonincendive Quartz Models
|
Series |
Sensors / Switches |
Enclosure |
Conduit Entries
|
Indicator |
|
|
Sensor Modules
|
33 |
SST N.O. Switching Sensor
Dual Module |
|
44 |
SST N.O. Switching Sensor
Dual Module |
Valve Communication
Terminals (VCTs)
|
92
|
DeviceNet VCT
|
|
93 |
Foundation Fieldbus
(Bus Powered; I.S.)
|
|
95
|
ModBus
|
|
96
|
AS-Interface
|
|
97
|
AS-Interface (with
extended addressing)
|
Expeditors (Proximity
Type)
|
82 |
DeviceNet |
|
83 |
Foundation Fieldbus |
|
85 |
Modbus |
|
86
|
AS-Interface |
|
87 |
AS-Interface (Ext Addr) |
Sensors / Switches
|
Function
|
2
|
(2) Switches
|
|
4 |
(4) Switches
|
|
5
|
Position Transmitter
with (2) or No Switches |
|
7
|
High Performance
Position Transmitter with (2) or No Switches |
|
8
|
Expeditor, Y or H switches only
|
|
Switch /
Sensor Type
|
P
|
SPST Maxx-Guard |
|
L
|
SPST Maxx-Guard (LED)
|
|
G*
|
SPDT Maxx-Guard |
|
H |
SPDT Maxx-Guard |
|
S
|
SPDT Maxx-Guard (LED) |
|
Y
|
Expeditor Only (3)
|
|
F
|
PNP Solid State
3-wire P&F |
|
X |
SST Sensor
(LED) |
|
E |
NPN Solid State
3-wire P&F |
|
O |
No Switches |
Intrinsically Safe
Type
|
J
|
SPST (Passive) |
|
M |
SPDT (Passive) |
|
K |
SPST Sensor |
|
N
|
P + F Namur Sensors |
|
O |
No Switches |
* G Switch is only FMus
approved. models including this switch do not
have cFM
approval |
Intrinsically Safe
Type
|
44 |
SPST (Passive) |
|
2A
|
(2) Special P&F Sensors |
|
|
C
|
Clear(NEC/CEC) |
|
E
|
Aluminum(NEC/CEC) |
|
|
02
|
(1) 3/4” NPT
&
(1) 1/2” NPT |
|
03
|
(1) 3/4” NPT
&
(2) 1/2” NPT |
|
|
SRA
|
Red-Closed
Green-Open
|
|
SGA
|
Green-Closed
Red-Open
|
|
S1A |
T1 3-way |
|
S2A |
T2 3-way |
|
S3A |
T3 3-way |
|
S4A |
T4 3-way |
|
S5A |
T5 3-way |
|
S0A |
No Indication |
|
SXA |
Special |
|
SCA |
Continuous |
|
|
Series |
Sensors / Switches |
Enclosure |
Conduit Entries
|
Indicator |
|
|
Sensor Modules
|
33 |
SST N.O. Switching Sensor
Dual Module |
Valve Communication
Terminals (VCTs)
|
92
|
DeviceNet VCT
|
|
93 |
Foundation Fieldbus
(Bus Powered; I.S.)
|
|
95
|
ModBus
|
|
96
|
AS-Interface
|
|
97
|
AS-Interface (with
extended addressing)
|
Expeditors (Proximity
Type)
|
82 |
DeviceNet |
|
83 |
Foundation Fieldbus |
|
85 |
Modbus |
|
86
|
AS-Interface |
Sensors / Switches
|
Function
|
2
|
(2) Switches
|
|
4 |
(4) Switches
|
|
5
|
Position Transmitter
with (2) or No Switches |
|
7
|
High Performance
Position Transmitter with (2) or No Switches |
|
8
|
Expeditor, Y or H switches only
|
|
Switch /
Sensor Type
|
P
|
SPST Maxx-Guard |
|
L
|
SPST Maxx-Guard (LED)
|
|
G*
|
SPDT Maxx-Guard |
|
H |
SPDT Maxx-Guard |
|
S
|
SPDT Maxx-Guard (LED) |
|
Y
|
Expeditor Only (3)
|
|
F
|
PNP Solid State
3-wire P&F |
|
E |
NPN Solid State
3-wire P&F |
|
X |
SST Sensor
(LED) |
|
O |
No Switches |
*
G Switch is only FMus
approved. models including this switch do not
have cFM
approval |
|
|
E
|
North American(NEC/CEC) |
|
|
02
|
(1) 3/4” NPT
&
(1) 1/2” NPT |
|
03
|
(1) 3/4” NPT
&
(2) 1/2” NPT |
|
|
SRA
|
Red-Closed
Green-Open
|
|
SGA
|
Green-Closed
Red-Open
|
|
S1A |
T1 3-way |
|
S2A |
T2 3-way |
|
S3A |
T3 3-way |
|
S4A |
T4 3-way |
|
S5A |
T5 3-way |
|
S0A |
No Indication |
|
SXA |
Special |
|
SCA |
Continuous |
|

|
Series
|
Function |
Enclosure |
Conduit /
Connectors
|
Indicator |
|
|
Sensor / Switching Modules
|
33 |
(2) SST N.O. Solid State Sensors |
|
34 |
(2) SST N.C. Solid State Sensors |
Intrinsically Safe Modules
|
44 |
(2)
Namur Sensors (DIN 19234)
|
Valve Communication Terminals (VCTs)
|
92
|
DeviceNet |
|
95
|
ModBus
|
|
96
|
AS-Interface
|
|
97
|
AS-Interface (with
extended addressing)
|
|
|
C
|
North American(NEC/CEC) |
|
|
02
|
(2) 1/2” NPT
|
|
05
|
(2)
M20 |
|
11
|
(1) 5-pin
Mini male connector
|
|
12
|
(1) 5-pin
& (1) 3-pin Mini connectors |
|
|
RA
|
Red-Closed
Green-Open
|
|
GA
|
Red-Open
Green-Closed
|
|
FA
|
Flow Line
|
|
1A
|
T-1
3-way
|
|
2A
|
T-2
3-way
|
|
XA
|
Special
|
|

|
Series
|
Function |
Enclosure |
Conduit /
Connectors
|
Indicator |
|
|
Valve Communication Terminals (VCTs)
|
96
|
AS-Interface
|
|
97
|
AS-Interface (with
extended addressing)
|
|
|
C
|
North American(NEC/CEC) |
|
|
02
|
(2) 1/2” NPT
|
|
05
|
(2)
M20 |
|
11
|
(1) 5-pin
Mini male connector
|
|
12
|
(1) 5-pin
& (1) 3-pin Mini connectors |
|
|
RA
|
Red-Closed
Green-Open
|
|
GA
|
Red-Open
Green-Closed
|
|
FA
|
Flow Line
|
|
1A
|
T-1
3-way
|
|
2A
|
T-2
3-way
|
|
XA
|
Special
|
|

|
Series |
Function |
Enclosure |
Conduit /
Connectors
|
Indicator |
|
|
Sensor / Switching Modules
|
33 |
(2) SST N.O. Solid State Sensors |
|
34 |
(2) SST N.C. Solid State Sensors |
Intrinsically Safe Modules
|
44 |
(2)
Namur Sensors (DIN 19234)
|
Valve Communication Terminals (VCTs)
|
92
|
DeviceNet |
|
95
|
ModBus
|
|
96
|
AS-Interface
|
|
97
|
AS-Interface (with
extended addressing)
|
|
|
C
|
North American(NEC/CEC) |
|
|
23
|
(1) 4-pin Micro connector
|
|
24
|
(2) 4-pin Micro connectors
|
|
25
|
(1) 5-pin Micro connector
|
|
26
|
(1) 5-pin & (1) 4-pin
Micro connectors
|
|
|
RA
|
Red-Closed
Green-Open
|
|
GA
|
Red-Open
Green-Closed
|
|
FA
|
Flow Line
|
|
1A
|
T-1
3-way
|
|
2A
|
T-2
3-way
|
|
XA
|
Special
|
|

|
Series |
Function |
Enclosure |
Conduit /
Connectors
|
Indicator |
|
|
Valve Communication Terminals (VCTs)
|
96
|
AS-Interface
|
|
97
|
AS-Interface (with
extended addressing)
|
|
|
C
|
North American(NEC/CEC) |
|
|
23
|
(1) 4-pin Micro connector
|
|
24
|
(2) 4-pin Micro connectors
|
|
25
|
(1) 5-pin Micro connector
|
|
26
|
(1) 5-pin & (1) 4-pin
Micro connectors
|
|
|
RA
|
Red-Closed
Green-Open
|
|
GA
|
Red-Open
Green-Closed
|
|
FA
|
Flow Line
|
|
1A
|
T-1
3-way
|
|
2A
|
T-2
3-way
|
|
XA
|
Special
|
|

|
Series |
Function |
Housing |
Conduit /
Connectors
|
Indicator |
|
|
|
30 |
SST Solid State Sensor N.O.
|
|
31 |
SST Solid State Sensor N.C.
|
|
|
|
|

Series |
Function |
Pneumatic
Valve |
Conduit
Entries
|
Visual
Indication |
Valve
Size |
|
|
|
33
|
(2) SST N.O.
Switching Sensors
|
|
34
|
(2) SST N.C.
Switching Sensors
|
|
44
|
(2) Namur Sensors (I.S.;
DIN 19234)
|
|
92
|
DeviceNet VCT
|
|
93
|
Foundation Fieldbus
(Bus Powered; I.S.)
|
|
94
|
Foundation Fieldbus (Externally
Powered)
|
|
95
|
ModBus
|
|
96
|
AS-Interface
|
|
97
|
AS-Interface (with
extended addressing)
|
|
|
|
|
|
11
|
No Solenoid
|
|
1A*
|
3-way Piezo
Direct
|
|
1B
|
3-way
24 VDC (1.8W)
|
|
1C
|
3-way
120 VAC (7.2W)
|
|
1D
|
3-way
24 VDC (0.5W)
|
|
1E
|
12VDC 3-way 0.5 Watt I.S. |
|
|
S02
|
(2) 1/2”
NPT
|
|
S05
|
(2) M20
|
|
S09
|
(2) Cable
Glands
|
|
S11
|
(1) 5-pin
Mini connector
|
|
S13
|
(1) 4-pin
Micro connector
|
|
S14 |
(2) 4-pin
Micro connector
|
|
S15
|
(1) 5-pin
Micro connector
|
|
S16
|
(1) 5-pin
Micro connector & (1) 4-pin
Micro connector |
|
|
R
|
Red Closed
|
|
G
|
Green Closed
|
|
|
S
|
1/4 to 2" (1/8" to 1 3/16 stroke
|
|
L
|
2" to 4" (1
3/16 to 2 1/4" stroke)
|
|

Series |
Function |
Pneumatic
Valve |
Conduit
Entries
|
Visual
Indication |
Valve
Size |
|
|
|
93
|
Foundation Fieldbus
(Bus Powered; I.S.)
|
|
96
|
AS-Interface
|
|
97
|
AS-Interface (with
extended addressing)
|
|
|
|
|
|
11
|
No Solenoid
|
|
1A*
|
3-way Piezo
Direct
|
|
1B
|
3-way
24 VDC (1.8W)
|
|
1D
|
3-way
24 VDC (0.5W)
|
|
|
S02
|
(2) 1/2”
NPT
|
|
S05
|
(2) M20
|
|
S09
|
(2) Cable
Glands
|
|
S11
|
(1) 5-pin
Mini connector
|
|
S13
|
(1) 4-pin
Micro connector
|
|
S14 |
(2) 4-pin
Micro connector
|
|
S15
|
(1) 5-pin
Micro connector
|
|
S16
|
(1) 5-pin
Micro connector & (1) 4-pin
Micro connector |
|
|
R
|
Red Closed
|
|
G
|
Green Closed
|
|
|
S
|
1/4 to 2" (1/8" to 1 3/16 stroke
|
|
L
|
2" to 4" (1
3/16 to 2 1/4" stroke)
|
|

Click this link to view approvals for previous