Approvals

Jump to:      Axiom    Quartz        Eclipse        Prism          Hawkeye

 

Axiom Models  

FM (C and US) Approved

Non-Incendive Apparatus

Class 1 Division 2 Groups A,B,C,D

Class II Division 2 Groups F,G

 


Axiom VCT's

Series

Sensor Modules

Pneumatic Valve

Enclosure

Conduit

Capabilities

Indicator

AMI

92

DeviceNet VCT

94

Foundation Fieldbus (Externally Powered)

95

ModBus

96

AS-Interface

97

AS-Interface (with extended addressing)

Single Solenoid

  No Ext Override External Override Latching Ext. Over.
24VDC (0.5W)
92, 94, 95, 96, 97
1D 3D 5D
24VDC (1.8W)
92, 94, 95, 96, 97
1B 3B 5B


Dual Solenoid Shuttle Piston

  No Ext Override External Override Latching Ext. Over.
24VDC (1.8W)
92, 94, 95, 96, 97
2B 4B 6B
24VDC (0.5W)
92, 94, 95, 96, 97
2D 4D 6D

 

 

 

A

North America
(NEC)

02

(2) 1/2” NPT

05

(2) M20

10

(1) 4-pin Mini male connector

11

(1) 5-pin Mini male connector

13

(1) 4-pin Micro male connector

15

(1) 5-pin Micro male connector

17

(1) 6-pin Micro male connector

18

(1) 8-pin Micro male connector

19

(1) 6-pin Mini male connector

20

(1) 7-pin Mini male connector

21

(1) 8-pin Mini male connector

S

Standard

RA

Red-Closed  Green-Open

GA

Green-Closed  Red-Open

1A or 2A

Three Way Flow Path

Series

Sensor Modules

Pneumatic Valve

Enclosure

Conduit

Capabilities

Indicator

AMI

93

Foundation Fieldbus (Bus Powered)

Single Piezo

  No Ext Override External Override Latching Ext. Over.
Piezo 1A 3A 5A


Dual Piezo Shuttle Piston

  No Ext Override External Override Latching Ext. Over.
Piezo 2A 4A 6A

A

North America
(NEC)

02

(2) 1/2” NPT

05

(2) M20

10

(1) 4-pin Mini male connector

11

(1) 5-pin Mini male connector

13

(1) 4-pin Micro male connector

15

(1) 5-pin Micro male connector

17

(1) 6-pin Micro male connector

18

(1) 8-pin Micro male connector

19

(1) 6-pin Mini male connector

20

(1) 7-pin Mini male connector

21

(1) 8-pin Mini male connector

S

Standard

RA

Red-Closed  Green-Open

GA

Green-Closed  Red-Open

1A or 2A

Three Way Flow Path

 

 

Axiom with Sensors

Series

Sensor Modules

Pneumatic Valve

Enclosure

Conduit

Capabilities

Indicator

AMI

33

SST N.O. Switching Sensor

Single Solenoid

  No Ext Override External Override Latching Ext. Over.
24VDC  or 120VAC Universal 1H 3H 5H


Dual Solenoid Shuttle Piston

  No Ext Override External Override Latching Ext. Over.
24VDC  or 120VAC Universal 2H 4H 6H

 

 

 

A

North America
(NEC)

02

(2) 1/2” NPT

05

(2) M20

10

(1) 4-pin Mini male connector

11

(1) 5-pin Mini male connector

13

(1) 4-pin Micro male connector

15

(1) 5-pin Micro male connector

17

(1) 6-pin Micro male connector

18

(1) 8-pin Micro male connector

19

(1) 6-pin Mini male connector

20

(1) 7-pin Mini male connector

21

(1) 8-pin Mini male connector

S

Standard

RA

Red-Closed  Green-Open

GA

Green-Closed  Red-Open

1A or 2A

Three Way Flow Path

Series

Sensor Modules

Pneumatic Valve

Enclosure

Conduit

Capabilities

Indicator

AMI

44

Namur Sensor (I.S.; DIN 19234)

Single Solenoid

  No Ext Override External Override Latching Ext. Over.
12VDC I.S. 1E 3E 5E


Dual Solenoid Shuttle Piston

  No Ext Override External Override Latching Ext. Over.
12VDC I.S. 2E 4E 6E

 

 

 

A

North America
(NEC)

02

(2) 1/2” NPT

05

(2) M20

10

(1) 4-pin Mini male connector

11

(1) 5-pin Mini male connector

13

(1) 4-pin Micro male connector

15

(1) 5-pin Micro male connector

17

(1) 6-pin Micro male connector

18

(1) 8-pin Micro male connector

19

(1) 6-pin Mini male connector

20

(1) 7-pin Mini male connector

21

(1) 8-pin Mini male connector

S

Standard

RA

Red-Closed  Green-Open

GA

Green-Closed  Red-Open

1A or 2A

Three Way Flow Path

 

 

 

Axiom Models  

FM (C and US) Approved

Non-Incendive Field Wiring Apparatus

Class 1 Division 2 Groups A,B,C,D

 


Axiom VCT's

Series

Sensor Modules

Pneumatic Valve

Enclosure

Conduit

Capabilities

Indicator

AMI

96

AS-Interface

97

AS-Interface (with extended addressing)

Single Solenoid

  No Ext Override External Override Latching Ext. Over.
24VDC (0.5W)
92, 94, 95, 96, 97
1D 3D 5D
24VDC (1.8W)
92, 94, 95, 96, 97
1B 3B 5B


Dual Solenoid Shuttle Piston

  No Ext Override External Override Latching Ext. Over.
24VDC (1.8W)
92, 94, 95, 96, 97
2B 4B 6B
24VDC (0.5W)
92, 94, 95, 96, 97
2D 4D 6D

 

 

 

A

North America
(NEC)

02

(2) 1/2” NPT

05

(2) M20

10

(1) 4-pin Mini male connector

11

(1) 5-pin Mini male connector

13

(1) 4-pin Micro male connector

15

(1) 5-pin Micro male connector

17

(1) 6-pin Micro male connector

18

(1) 8-pin Micro male connector

19

(1) 6-pin Mini male connector

20

(1) 7-pin Mini male connector

21

(1) 8-pin Mini male connector

S

Standard

RA

Red-Closed  Green-Open

GA

Green-Closed  Red-Open

1A or 2A

Three Way Flow Path

Series

Sensor Modules

Pneumatic Valve

Enclosure

Conduit

Capabilities

Indicator

AMI

93

Foundation Fieldbus (Bus Powered)

Single Piezo

  No Ext Override External Override Latching Ext. Over.
Piezo 1A 3A 5A


Dual Piezo Shuttle Piston

  No Ext Override External Override Latching Ext. Over.
Piezo 2A 4A 6A

A

North America
(NEC)

02

(2) 1/2” NPT

05

(2) M20

10

(1) 4-pin Mini male connector

11

(1) 5-pin Mini male connector

13

(1) 4-pin Micro male connector

15

(1) 5-pin Micro male connector

17

(1) 6-pin Micro male connector

18

(1) 8-pin Micro male connector

19

(1) 6-pin Mini male connector

20

(1) 7-pin Mini male connector

21

(1) 8-pin Mini male connector

S

Standard

RA

Red-Closed  Green-Open

GA

Green-Closed  Red-Open

1A or 2A

Three Way Flow Path

 

 

Quartz Models  

FM and CSA Approved to:

Class I Division 2  Groups A,B,C,D

Class II Division 2 Groups F,G

 

 

Nonincendive Quartz Models

Series

Sensors / Switches

Enclosure

Conduit Entries

Indicator

 

QN

Sensor Modules

33 SST N.O. Switching Sensor Dual Module
44 SST N.O. Switching Sensor Dual Module

 

Valve Communication Terminals (VCTs)

92

DeviceNet VCT

93 Foundation Fieldbus (Bus Powered; I.S.)

95

ModBus

96

AS-Interface

97

AS-Interface (with extended addressing)

 

Expeditors (Proximity Type)

82

DeviceNet

83

Foundation Fieldbus

85

Modbus

86

AS-Interface

87

AS-Interface (Ext Addr)

 

Sensors / Switches

Function

2

(2) Switches

4

(4) Switches

5

Position Transmitter with (2) or No Switches

7

High Performance Position Transmitter with (2) or No Switches

8

Expeditor, Y or H switches only


 

Switch / Sensor Type

P

SPST Maxx-Guard

L

SPST Maxx-Guard (LED)

G*

SPDT Maxx-Guard

H

SPDT Maxx-Guard

S

SPDT Maxx-Guard (LED)

Y

Expeditor Only (3)

F

PNP Solid State
3-wire P&F

X

SST Sensor (LED)

K

SPST Sensor

E

NPN Solid State
3-wire P&F

O

No Switches

 

Intrinsically Safe Type

J

SPST (Passive)

M

SPDT (Passive)

N

P + F Namur Sensors

 

G Switch is only FMus

approved. models including this switch do not have cFM approval

6X

(6) SST Sensors (LED)

2A

(2) Special P&F Sensors

 

C

Clear(NEC/CEC)

E

Aluminum(NEC/CEC)

02

(1) 3/4” NPT & (1) 1/2” NPT

03

(1) 3/4” NPT & (2) 1/2” NPT

SRA

Red-Closed  Green-Open

SGA

Green-Closed  Red-Open

S1A

T1 3-way

S2A

T2 3-way

S3A

T3 3-way

S4A

T4 3-way

S5A

T5 3-way

S0A

No Indication

SXA

Special

SCA

Continuous

 

Series

Sensors / Switches

Enclosure

Conduit Entries

Indicator

 

QX

Sensor Modules

33 SST N.O. Switching Sensor Dual Module

 

Valve Communication Terminals (VCTs)

92

DeviceNet VCT

93 Foundation Fieldbus (Bus Powered; I.S.)

95

ModBus

96

AS-Interface

97

AS-Interface (with extended addressing)

 

Expeditors (Proximity Type)

82

DeviceNet

83

Foundation Fieldbus

85

Modbus

86

AS-Interface

 

Sensors / Switches

Function

2

(2) Switches

4

(4) Switches

5

Position Transmitter with (2) or No Switches

7

High Performance Position Transmitter with (2) or No Switches

8

Expeditor, Y or H switches only

Switch / Sensor Type

P

SPST Maxx-Guard

L

SPST Maxx-Guard (LED)

G*

SPDT Maxx-Guard

H

SPDT Maxx-Guard

S

SPDT Maxx-Guard (LED)

Y

Expeditor Only (3)

F

PNP Solid State
3-wire P&F

E

NPN Solid State
3-wire P&F

X

SST Sensor (LED)

O

No Switches

 

G Switch is only FMus

approved. models including this switch do not have cFM approval

 

6X

(6) SST Sensors (LED)

E

North American(NEC/CEC)

02

(1) 3/4” NPT & (1) 1/2” NPT

03

(1) 3/4” NPT & (2) 1/2” NPT

SRA

Red-Closed  Green-Open

SGA

Green-Closed  Red-Open

S1A

T1 3-way

S2A

T2 3-way

S3A

T3 3-way

S4A

T4 3-way

S5A

T5 3-way

S0A

No Indication

SXA

Special

SCA

Continuous

 

Eclipse Models (EN Series)

FM (C and US) Approved

Non-Incendive Apparatus

Class I Division 2  Groups A,B,C,D

Class II Division 2 Groups F,G

 

Series

Function

Enclosure

Conduit / Connectors

Indicator

EN

 

 

Sensor / Switching Modules

33 (2) SST N.O. Solid State Sensors
34 (2) SST N.C. Solid State Sensors

 

Intrinsically Safe Modules

44 (2) Namur Sensors (DIN 19234)

 

Valve Communication Terminals (VCTs)

92

DeviceNet

95

ModBus

96

AS-Interface

97